I-01
Capture Demonstrator
Method & assumptions
This instrument demonstrates the core capture problem this standard exists to address: whether a buoyant cooking plume, as it rises and expands, stays inside the hood’s capture envelope or escapes it. Every other instrument on this site isolates one variable from this same model — this one lets you move all of them at once.
Reference readings
Representative values below are computed directly from the same capture-fraction module (physics/capture.mjs) driving the instrument above — a 48-inch hood over the papers’ reference source, a medium gas grill with a 24 × 21-inch cooking surface (RB-001 Table 3.1), at the fixed 30-inch mounting rise; live values update as you move the controls. The table is regenerated by scripts/generate-reference-tables.mjs, never typed by hand.
| Wind direction | Wind speed | Wall (48″ × 36″) | Island (48″ × 40″) |
|---|---|---|---|
| Side (across the hood) | 0 mph | 87% | 87% |
| Side (across the hood) | 5 mph | 51% | 51% |
| Side (across the hood) | 8 mph | 20% | 20% |
| Side (across the hood) | 10 mph | 8% | 8% |
| Side (across the hood) | 15 mph | 0% | 0% |
| Rear (wall side) | 0 mph | 97% | 76% |
| Rear (wall side) | 5 mph | 92% | 39% |
| Rear (wall side) | 8 mph | 88% | 12% |
| Rear (wall side) | 10 mph | 84% | 4% |
| Rear (wall side) | 15 mph | 71% | 0% |
Two things in the table are deliberate. First, under a side wind — blowing across the hood face, parallel to a rear wall — the wall and island columns are identical: the wall is parallel to the flow and shelters nothing, so capture is set entirely by the 12 inches of overhang beyond each end of the cooking surface — the side-wind axis — and it falls from about 87% in still air to 51% at 5 mph and 20% at 8 mph. Second, under a rear wind the wall is doing real work: RB-006 finds a solid rear wall cuts the wind the plume feels by 60–80% within its recirculation zone [RB-006 §3.9.2], so the wall-mounted hood still holds about 88% at 8 mph while the island hood — with only 9.5 inches of front-to-back overhang on each side — has fallen to about 12%. That is why RB-006 grades installations by wind exposure and direction, not by hood shape alone [RB-006 §3.8].
The two 0 mph rows differ because the OVS capture model — which reads a Gaussian plume (σ = 1.5·b_T, a model assumption) against RB-006 §3.4’s deflection-versus-overhang thresholds — is one-dimensional along the wind axis: it integrates that plume across the hood’s overhang along that axis only, so its still-air figure is the aperture fraction along that axis — about 87% end to end (the side-wind axis, 12 inches beyond each end of the cooking surface), and front to back (the rear-wind axis) about 97% for the wall hood and 76% for the island — not a two-dimensional capture of the whole plume. Still-air percentages elsewhere on this site name the axis they were evaluated along.
The 87% still-air figure along the side-wind axis is itself a message about hood size. The papers’ recommended hood for this grill at 30 inches is 57 inches wide by 53 inches deep (RB-002 Tables 3.6b and 3.7); the 48-inch preset is 84% of that width, which RB-008 Table 3.10 classes as marginal — “80–85% at best” — and advises fixing with width, not airflow [RB-008 §3.10]. The default preset is undersized by design so the effect of wind is visible; drag the width control to 57 inches to see the paper’s own design point, which the model reads at about 96% in still air and 72% at 5 mph along the side-wind axis (RB-006 Table 3.10 prints “>95%” and “70–75%” for that hood [RB-006 §3.10]); along the rear-wind axis, where its 53-inch depth leaves 16 inches of overhang front and back, the same island hood reads about 95% in still air.
How the demonstrator works
The demonstrator combines three results from the research program into a single interactive model:
- Plume width by height — the Heskestad half-width b_T = 0.12 (z − z_0) from RB-001 §2.2 and RB-002 App. A.3, which sets how far the plume has expanded by the time it reaches the hood. The plume at hood height is modeled as Gaussian with σ = 1.5 b_T, the radius of RB-002’s time-averaged 90% flux contour [RB-002 §3.4].
- Hood geometry and capture — the aperture is the hood’s overhang beyond the cooking surface along the wind axis, exactly as RB-006 §3.4 states its escape thresholds: a centerline deflected to one b_T inside the hood edge loses about 25% of the plume; to the edge, about 50% [RB-006 §3.4]. The wall-mount rear-wind case reflects the upwind tail per RB-005 §3.4.4.
- Wind deflection — the RB-006 §3.1 closed-form deflection δ = 0.35 U_w z / u_0(z), applied to the wind the plume actually feels after any side panels or rear wall [RB-006 §3.1, §3.9].
Default preset is a 48-inch island installation (island-48) — no wall, no side panels, so wind sensitivity is at its maximum. This is illustrative, not a design tool: it does not size exhaust airflow, so it should not be used on its own to specify an installation. Use the Outdoor Range Hood CFM Calculator for that.
Source Papers
- RB-002: Entrainment and Lateral Plume Spread — Plume width model and recommended hood dimensions
- RB-005: Hood Geometry and Capture — Overhang and wall-mount capture geometry
- RB-006: Wind Interaction and Crossflow — Closed-form deflection, escape thresholds, rear-wall sheltering
Related
Questions
- How far should an outdoor hood extend past the grill?
- Does wind really affect an outdoor range hood?
Papers
Outdoor Ventilation Standard (2026). “Capture Demonstrator.” Interactive Tool, Outdoor Ventilation Standard. https://outdoorventilationstandard.com/tools/capture-demonstrator/